MELSEC-F Series
Mitsubishi
คุณสมบัติที่หลากหลายและการกำหนดค่าระบบที่ยืดหยุ่นในขนาดที่กะทัดรัด
MELSEC-F series เป็น PLC รวมแหล่งจ่ายไฟ, CPU และ I/O ไว้ในหน่วยเดียวที่มีขนาดกะทัดรัด
ตอบสนองความต้องการของผู้ใช้ที่หลากหลายด้วยตัวเลือกสำหรับ I/O, อะนาล็อก, การกำหนดตำแหน่ง และการขยายเครือข่ายแบบเปิด
list of contents
Main Unit

All-in-one power supply, CPU, and I/O main unit. Built-in features include high-speed counters and positioning outputs.
FX PLC Main Unit

A wide lineup in FX series offers you many choices to fit to your budget and application.
You are sure to find a model that fulfills your needs.
FX Series Lineup | |
---|---|
For high speed, | Here |
For high speed, | Here |
For communication, | Here *1: 14pt, 24pt models can only connect 1 board |
For reduced space and | Here |
For communication, | Here |
Explanation of the icons | |
| Depending on control points, total 256 I/O extension devices can be connected. |
FX3U/FX3UC can count at high speed input frequency 100kHz (1-phase 6pts), 50kHz (2-phase 2pts), 10kHz (1-phase 2pts). | |
Depending on control points, total 384 I/O extension devices can be connected. | |
FX3S/FX3GC has 2 axes simple positioning function built into the main unit. | |
Depending on the purpose, various special function blocks can be connected. | |
FX3G/FX3U/FX3UChas 3 axes simple positioning built into the main unit. | |
Function can be easily added by mounting a function expansion board to the main unit. | |
I/O can be connected in connector format, reducing wiring effort. | |
In FX3UC-32MT-LT, CC-Link/LT master functionality is built-in. | |
1 phase: 60 kHz x 4 pts/ 10 kHz x 2 pts 2 phase: 30 kHz x 2 pts/ 5 kHz 1 pt | |
1 phase: 60 kHz x 2 pts/ 10 kHz x 4 pts 2 phase: 30 kHz x 1 pt/ 5 kHz 1 pt | |
In FX3S-30MR/ES-2AD, FX3S-30MT/ES-2AD, and FX3S-30MT/ESS-2AD, 2ch analog input (current input) function is built-in. |
I/O Extension

Both [I/O Extension Units] with a built-in power supply and [I/O Extension Blocks] without a power supply are available in various I/O sizes and configurations.
FX series I/O extension devices are divided into “extension blocks” and “powered extension units”.
“Powered extension units” have built-in power supply and also extend I/O at the same time.
“Extension blocks” adjust the I/O of the main unit or powered extension units in 8 point or 16 point units.
Extension units
Powered extension units are I/O extension devices with built-in power supply.
Like with the main unit, various I/O devices and special devices can be connected after a powered extension unit.
Model | Total number | Number of input/output points | Applicable FX PLC | |||||||||
Input | Output | FX | FX | FX | FX | FX | ||||||
AC Power Type | ||||||||||||
11111111111111 | FX2N-32ER | 32 points | 16 points | 24 V DC | 16 points | Relay | × | ○ | ○ | × | × | |
FX2N-32ER-ES/UL | 24 V DC | |||||||||||
FX2N-32ES | 24 V DC | Triac | ||||||||||
FX2N-32ET | 24 V DC | Transistor | ||||||||||
FX2N-32ET-ESS/UL | 24 V DC | Transistor | ||||||||||
| FX2N-48ER | 48 points | 24 points | 24 V DC | 24 points | Relay | × | ○ | ○ | × | × | |
FX2N-48ER-ES/UL | DC24V | |||||||||||
FX2N-48ET | 24 V DC | Transistor | ||||||||||
FX2N-48ET-ESS/UL | 24 V DC | Transistor | ||||||||||
| FX2N-48ER-UA1/UL | 48 points | 24 points | 100 V AC | 24 points | Relay | × | ○ | ○ | × | × | |
DC Power Type | ||||||||||||
| FX2N-48ER-D | 48 points | 24 points | 24 V DC | 24 points | Relay | × | ○ | ○ | × | × | |
FX2N-48ER-DS | 24 V DC | |||||||||||
FX2N-48ET-D | 24 V DC | Transistor | ||||||||||
FX2N-48ET-DSS | 24 V DC | Transistor |
Regarding connection cable
A connection cable (length: 55mm), used to connect to the the right side of the device in front of the powered extension unit, is included with the powered extension unit. To extend the distance of the connection, please use the optional “extension cable”.
Function expansion board
The expansion board is designed to add the input and output terminal whose points are small to FX3S or FX3G PLCs. The board can be built in the PLC.
Model | Total | Number of input/output points | Applicable FX PLC | |||||||||
Input | Output | FX | FX | FX | FX | FX | ||||||
1111111111 | FX3G-4EX-BD | 4 | 4 | 24 V DC | – | – | *1 | *2 | × | × | × | |
| FX3G-2EYT-BD | 2 | – | – | 2 | Transistor | *1 | *2 | × | × | × |
*1: Supported by FX3S ver.1.10 and later.
*2: Supported by FX3G ver.2.20 and later.
Extension blocks
Extension block is an I/O extension device that receives power from the main unit or powered extension unit.
It can be connected in 8 point or 16 point units. The connectable number of points is determined by each main unit or powered extension unit
Model | Total number | Number of input/output points | Applicable FX PLC | |||||||||
Input | Output | FX | FX | FX | FX | FX | ||||||
Input/output extension blocks | ||||||||||||
111111111 | FX2N-8ER | 8 points | 4 points | 24 V DC | 4 points | Relay | × | ○ | ○ | *1 | *1 | |
FX2N-8ER-ES/UL | DC24V | |||||||||||
FX2N-8EX | 8 points | 24 V DC | – | – | ||||||||
FX2N-8EX-ES/UL | DC24V | |||||||||||
FX2N-8EX-UA1/UL | 100 V AC | |||||||||||
| FX2N-16EX | 16 points | 16 points | 24 V DC | × | ○ | ○ | *1 | *1 | |||
FX2N-16EX-ES/UL | 24 V DC | |||||||||||
FX2N-16EX-C | 24 V DC | |||||||||||
FX2N-16EXL-C | 5 V DC | |||||||||||
Output extension blocks | ||||||||||||
| FX2N-8EYR | 8 points | – | – | 8 points | Relay | × | ○ | ○ | *1 | *1 | |
FX2N-8EYR-ES/UL | ||||||||||||
FX2N-8EYR-S-ES/UL | Relay | |||||||||||
FX2N-8EYT | Transistor | |||||||||||
FX2N-8EYT-H | ||||||||||||
FX2N-8EYT-ESS/UL | Transistor | |||||||||||
| FX2N-16EYR | 16 points | 16 points | Relay | × | ○ | ○ | *1 | *1 | |||
FX2N-16EYR-ES/UL | ||||||||||||
FX2N-16EYS | Triac | |||||||||||
FX2N-16EYT | Transistor | |||||||||||
FX2N-16EYT-ESS/UL | Transistor | |||||||||||
FX2N-16EYT-C | Transistor |
*1 :For connection to FX3GC or FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*2 :Depending on the model name of the main unit, I/O extension device connection may or may not be allowed. For details, refer to the manual of the main unit.
Regarding connection cable
A connection cable, used to connect to the right side of the device in front of the extension block, is included with the extension block.
To extend the distance of the connection, please use the optional “extension cable (FX0N-30EC/FX0N-65EC)” and “connector conversion adapter (FX2N-CNV-BD)”.
Extension block for connector type main unit (FX3GC, FX3UC)
These I/O extension devices can be directly connected to FX1NC, FX3GC, FX2NC, FX3UC PLCs.
They can be compactly extended because connection cables are not needed.
Model | Total number | Number of input/output points | Applicable FX PLC | |||||||||
Input | Output | FX | FX | FX | FX | FX | ||||||
Input extension blocks | ||||||||||||
11111 | FX2NC-16EX-T | 16 points | 16 points | 24 V DC | – | – | × | × | × | * | * | |
FX2NC-16EX-T-DS | DC24V | |||||||||||
| FX2NC-16EX | DC24V | ||||||||||
FX2NC-16EX-DS | DC24V | |||||||||||
FX2NC-16EX-D/UL | DC24V | |||||||||||
| FX2NC-32EX | 32 points | 32 points | 24 V DC | ||||||||
FX2NC-32EX-DS | DC24V | |||||||||||
FX2NC-32EX-D/UL | DC24V | |||||||||||
Output extension blocks | ||||||||||||
| FX2NC-16EYR-T | 16 points | – | – | 16 points | Relay | × | × | × | * | * | |
FX2NC-16EYR-T-DS | ||||||||||||
| FX2NC-16EYT | Transistor | ||||||||||
FX2NC-16EYT-DSS | Transistor | |||||||||||
FX2NC-16EYT-D/UL | Transistor | |||||||||||
| FX2NC-32EYT | 32 points | 32 points | Transistor | ||||||||
FX2NC-32EYT-DSS | Transistor | |||||||||||
FX2NC-32EYT-D/UL | Transistor | |||||||||||
Input/output extension blocks | ||||||||||||
| FX2NC-64ET | 64 points | 32 points | 24 V DC | 32 points | Transistor | × | × | × | * | * |
*: Depending on the model name of the main unit, I/O extension device connection may or may not be allowed. For details, refer to the manual of the main unit
Analog Control

Options for analog inputs and outputs, temperature sensor inputs, and temperature control are available.
By using analog input blocks and output blocks, analog quanties (voltage, current, etc.) can be input or output. Analog control, which is indispensable in FA control, can be easily realized with PLC.
Analog expansion board (A/D conversion, D/A conversion)
Model | Input specifications | Applicable FX PLC | |||||||
Item | Input voltage | Input current | FX | FX | FX | FX | FX | ||
FX3G-2AD-BD | Input | 0 to 10 V DC | 4 to 20 mA DC | *3 | *1*2 | × | × | × | |
Resolution | 2.5 mV | 8 μA | |||||||
FX3G-1DA-BD | Output | 0 to 10 V DC | 4 to 20 mA DC | *3 | *1*2 | × | × | × | |
Resolution | 2.5 mV | 8 μA |
*1: Supported by FX3G ver. 1.10 and later.
*2: FX3G 14 pt, 24 pt models: 1 board. 40 pt, 60 pt models: 2 boards.
*3: Function expansion board and FX3S-CNV-ADP cannot be used together.
Mixed Analog Input/Output (A/D conversion, D/A conversion)
Model | Input/output specifications | Applicable FX PLC | |||||||
Item | Input/output voltage | Input/output current | FX | FX | FX | FX | FX | ||
FX3U-3A-ADP | Input | 0 to 10 V DC | 4 to 20 mA DC | *7 | *1*6 | *2 | ○ | *3 | |
Output | 0 to 10 V DC | 4 to 20 mA DC | |||||||
Resolution | [Input voltage] | [Input current] | |||||||
FX2N-5A | Input | -100 to 100 mV DC | -20 to 20 mA DC | × | ○ | ○ | *8 | *4*5 | |
Output | -10 to 10 V DC | 0 to 20 mA DC, | |||||||
Resolution | 50 μV | 1.25 μA,10 μA |
*1: Supported by FX3G ver.1.20 and later. For connection to FX3G, FX3G-CNV-ADP is required.
*2: Supported by FX3U ver.2.61 and later. For connection to FX3U, function expansion board is required.
*3: Supported by FX3UC ver.2.61 and later. When connecting to FX3UC-32MT-LT(-2), function expansion board is required.
*4: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*5: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D, FX3UC-**MT/DSS, FX3UC-16MR/D(S)-T: 8 units.
*6: FX3G 14 pt, 24 pt models: 1 board. 40 pt, 60 pt models: 2 boards.
*7: For connection to FX3S, FX3S-CNV-ADP is required.
*8: When connecting to FX3GC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
Analog Input (A/D conversion)
Model | Input specifications | Applicable FX PLC | |||||||
Item | Input voltage | Input current | FX | FX | FX | FX | FX | ||
FX3S-30MR/ES-2AD | Input | 0 to 10 V DC | – | – | – | – | – | – | |
Resolution | 10 mV | – | |||||||
FX2N-2AD | Input | 0 to 10 V DC, | 4 to 20 mA DC | × | ○ | ○ | *9 | *1*2 | |
Resolution | 2.5 mV | 4 μA | |||||||
FX3U-4AD | Input | -10 to 10 V DC | -20 to 20 mA DC, | × | ○ | ○ | *9 | *1*2 | |
Resolution | 0.32 mV | 1.25 μA | |||||||
FX3U-4AD-ADP | Input | 0 to 10 V DC | 4 to 20 mA DC | *8 | *4*3 | *5 |
| *5*6 | |
Resolution | 2.5 mV | 10 μA | |||||||
FX3UC-4AD | Input | -10 to 10 V DC | 4 to 20 mA DC, | × | × | × |
| *7*2 | |
Resolution | 0.32 mV | 1.25 μA | |||||||
FX2N-8AD | Input | -10 to 10 V DC | 4 to 20 mA DC | × |
|
| *9 | *1*2 | |
Resolution | 0.63 mV | 2.5 μA |
*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D, FX3UC-**MT/DSS, FX3UC-16MR/D(S)-T: 8 units.
*3: FX3G 14 pt, 24 pt models: 1 board. 40 pt, 60pt models: 2 boards.
*4: When connecting to FX3G, FX3G-CNV-ADP is required.
*5: When connecting to FX3U, function expansion board is required.
*6: FX3UC-32MT-LT supported from version 1.20 or later.
*7: FX3UC-32MT-LT supported from version 1.30 or later.
*8: When connecting to FX3S, FX3S-CNV-ADP is required.
*9: When connecting to FX3GC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
Analog Output (D/A conversion)
Model | Output specifications | Applicable FX PLC | |||||||
Item | Output voltage | Output current | FX | FX | FX | FX | FX | ||
FX2N-2DA | Output | 0 to 10 V DC, | 4 to 20 mA DC | × |
|
| *8 | *1*2 | |
Resolution | 2.5 mV | 4 μA | |||||||
FX3U-4DA | Output | -10 to 10 V DC | 0 to 20 mA DC | × |
|
| *8 | *1*2 | |
Resolution | 0.32 mV | 0.63 μA | |||||||
FX3U-4DA-ADP | Output | 0 to 10 V DC | 4 to 20 mA DC | *7 | *3*4 | *5 | ○ | *5*6 | |
Resolution | 2.5 mV | 4 μA |
*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D, FX3UC-**MT/DSS, FX3UC-16MR/D(S)-T: 8 units.
*3: FX3G 14 pt, 24 pt models: 1 board. 40 pt, 60 pt models: 2 boards.
*4: When connecting to FX3G, FX3G-CNV-ADP is required.
*5: When connecting to FX3U, FX3UC-32MT-LT(-2), function expansion board is required.
*6: FX3UC-32MT-LT supported from version 1.20 or later.
*7: When connecting to FX3S, FX3S-CNV-ADP is required.
*8: When connecting to FX3GC, FX2NC-CNV-IF or FX3UC-1PS-5V is required..
High-Speed Counting

Options are available to increase the performance of the built-in high-speed counters or provide additional high-speed counting capacity.
Using high speed counters, high speed signals from encoder and sensors can be counted.
Because FX PLC has built-in high performance high speed counters, high speed control is possible with a simple program. A high speed counter block with hardware comparator is also available.
High speed counter block/adapter
Model | Type | Highest response | Hardware comparison | 2-phase counter | Applicable FX PLC | |||||
FX | FX | FX | FX | FX | ||||||
FX2N-1HC | 1-phase | Max. 50 kHz | ○ | – | × | × | ○ | × | *2*3 | |
1-phase | Max. 50 kHz | |||||||||
2-phase | 1 edge count: | ○ | ||||||||
FX3U-2HC | 1-phase | Max. 200 kHz | ○ | – | × | × | ○ | × | *2 | |
1-phase | Max. 200 kHz | |||||||||
2-phase | 1 edge count: | ○ | ||||||||
FX2NC-1HC | 1-phase | Max. 50 kHz | ○ | – | × | × | × | × | *3 | |
1-phase | Max. 50 kHz | |||||||||
2-phase | 1 edge count: | ○ | ||||||||
FX3U-4HSX-ADP | 1-phase | Max. 200 kHz | × | ○ | × | × | *1 | × | × | |
1-phase | Max. 200 kHz | |||||||||
2-phase | 1 edge count: |
*1: When used together with analog or communication adapters, function expansion board is required.
*2: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*3: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D,FX3UC-**MT/DSS,FX3UC-16MR/D(S)-T: 8 units.
Built-in high speed counter function (high speed input adapter function)
FX3S Series PLC
Type | Counter No. | Max. response | Supported high speed processing instructions | High | 2 phase | FX3U-4HSX-ADP | |||||
When | When | High | High | High | Counter | High | |||||
1- | C235, | overall frequency | ○ | ○ | ○ | × | × | × | – | × | |
C237 to C240, | |||||||||||
1- | C246 | ||||||||||
C247, | |||||||||||
2- | C251 | × | |||||||||
C252, |
*: Regarding high speed counter reponse frequency, the overall frequency is limited. For details, please refer to the programming manual.
FX3G, FX3GC Series PLC
Type | Counter No. | Max. response | Supported high speed processing instructions | High | 2 phase | FX3U-4HSX-ADP | |||||
When | When | High | High | High | Counter | High | |||||
1- | C235, | overall | ○ | ○ | ○ | × | × | × | – | × | |
C237, | |||||||||||
1- | C246, | ||||||||||
C247 to C250 | |||||||||||
2- | C251, | × | |||||||||
C252 to C255, |
*: Regarding high speed counter reponse frequency, the overall frequency is limited. For details, please refer to the programming manual.
FX3U, FX3UC Series PLC
Type | Counter No. | Max. response | Supported high speed processing instructions | High | 2 phase | FX3U-4HSX-ADP | ||||||
When | When | High | High | High | Counter | High | ||||||
1- | C235 to C240 | 40 kHz | 40- | ○ | ○ | ○ | ○ | ○ | ○ | – | 200kHz | |
C244(OP), | 10 kHz | 200 kHz | ||||||||||
C241 to C245 | 40 kHz | – | ||||||||||
1- | C246, | 40 kHz | 200 kHz | |||||||||
C247 to C250 | 40 kHz | – | ||||||||||
2- | C251, | 1 edge count | 40 kHz | ○ | 100 kHz | |||||||
4 edge count | 10 kHz | (40- | ||||||||||
C252, | 1 edge count | 40 kHz | 40- | – | ||||||||
4 edge count | 10 kHz | (40- |
*: Regarding high speed counter reponse frequency, the overall frequency is limited. For details, please refer to the programming manual.
Variety of functions
Built-in high speed counter numbers and allocation
Maximum frequency that the PLC can process
High speed comparison results can be obtained by a simple program and no calculation delay
FX3U, FX3U PLC counter mod
Positioning Control

มีเอาต์พุตพัลส์ความเร็วสูงและตัวเลือกการกำหนดตำแหน่ง SSCNETIII
ซีรีส์ FX นำเสนอ PLC ราคาประหยัดพร้อมคำแนะนำการวางตำแหน่งในตัวและบล็อกเอาต์พุตพัลส์ที่สามารถควบคุมตำแหน่งได้หลากหลาย
นอกจากนี้ยังมีโมดูลการกำหนดตำแหน่งเฉพาะสำหรับการควบคุมที่ซับซ้อนและหลายแกน การควบคุมการแก้ไข
High-speed output special adapter
Model | Number of | Maximum | Applicable FX PLC | ||||||
FX | FX | FX | FX | FX | |||||
11111 | FX3U-2HSY-ADP | Independent two axes | 200kHz | × | × | * | × | × |
*: When used together with analog or communication adapters, function expansion board is required
Pulse output block
Model | Number of | Maximum | Applicable FX PLC | ||||||
FX | FX | FX | FX | FX | |||||
| FX3U-1PG | Independent one axis | 200kHz | × | × | *3 | × | *1*3 | |
| FX2N-10PG | Independent one axis | 1MHz(1 Hz to 1 MHz | × | × | ○ | × | *1*2 | |
*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D,FX3UC-**MT/DSS,FX3UC-16MR/D(S)-T: 8 units.
*3: FX3U, FX3UC supported from version 2.20 or lat
SSCNET
Model | Number of | Maximum | Applicable FX PLC | ||||||
FX | FX | FX | FX | FX | |||||
| FX3U-20SSC-H | Two axes | – | × | × | ○ | × | *1*2 |
*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D,FX3UC-**MT/DSS,FX3UC-16MR/D(S)-T: 8 units.
Positioning dedicated unit
Model | Number of | Maximum | Applicable FX PLC | ||||||
FX | FX | FX | FX | FX | |||||
| FX2N-10GM | Independent one axis | 200kHz | × | × | ○ | × | *1*2 | |
| FX2N-20GM | Two axes | 200kHz |
*1: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*2: FX3UC-32MT-LT(-2): 7 units. FX3UC-**MT/D,FX3UC-**MT/DSS,FX3UC-16MR/D(S)-T: 8 units.
For FX2N-10GM/FX2N-20GM positioning teaching panel
Model | Product |
E-20TP-SET0 | FX2N-10GM, FX2N-20GM |
E-20TP-E-SET0 |
Angle control unit
Model | Number of | Maximum | Applicable FX PLC | ||||||
FX | FX | FX | FX | FX | |||||
1111111111111 | FX2N-1RM-SET*1 | One axis | 720 divisions/rotation (0.5 degree) | × | × | ○ | × | *2*3 | |
FX2N-1RM-E-SET*1 |
*1: FX2N-1RM-SET is a Japanese domestic only product. For use overseas, please select FX2N-1RM-E-SET, which supports overseas standards.
*2: Extension cable cannot be used.
*3: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
PLC built-in pulse output functions and positioning functions
Items | FX3S | FX3G,FX3GC | FX3U,FX3UC | |
Number of axis | Two axes | [FX3G] | Three axes | |
Number of controlled axis | Independent two axes | [FX3G] | Independent three axes | |
Maximum frequency | 100 kHz | 100 kHz | 100 kHz | |
Programming languages | Sequence programs | Sequence programs | Sequence programs | |
Compatible main unit | Transistor | Transistor | Transistor | |
Pulse | Pulse Y Output | ○ | ○ | ○ |
Acceleration/Deceleration Setup | ○ | ○ | ○ | |
Pulse output type | Pulse train | Pulse train | Pulse train | |
Positioning | Absolute Current Value Read | ○ | ○ | ○ |
Dog Search | ○ | ○ | ○ | |
Zero Return | ○*1 | ○*1 | ○*1 | |
Variable Speed Pulse Output | ○ | ○ | ○ | |
Drive to Increment | ○ | ○ | ○ | |
Drive to Absolute | ○ | ○ | ○ | |
Interrupt Positioning | × | × | ○ | |
Batch Data Positioning Mode | × | ○ | ○*2 | |
Pulse output type | Pulse train + direction | Pulse train + direction | Pulse train + direction | |
| Details | Details | Details |
*1: No DOG search function Decelerate when near point DOG turns ON, and stop when near point DOG turns OFF (Different from zero return operation with zero signal count)
*2: FX3UC-32MT-LT supported from version 2.20 or later.
Optional parts and spare parts
Servo motor connection cable
Model | Length | Description | |
| E-GMH-200CAB | 2 m | [MR-H series servo amplifer connection cable] |
| E-GMJ-200CAB | 2 m | [MR-J series servo amplifer connection cable] |
| E-GMJ2-200CAB1A | 2 m | [MR-J2, MR-J2-Super series servo amplifer connection cable] |
| E-GMC-200CAB | 2 m | [MR-C series servo amplifer connection cable] |
| E-GM-200CAB | 2 m | [General purpose connection cable] |
Connector for self-manufactured I/O cable (an electric wire or a crimp tool is not enclosed.)
Model | Description | |
| FX2C-I/O-CON | [Flat Cable Connector] |
| FX2C-I/O-CON-S | [Connector for bared wire] |
FX2C-I/O-CON-SA | [Connector for bared wire] |
Extension connection cable
Model | Length | Description | |
| FX2N-GM-65EC | 65 cm | [Connection extension cable between PLC and FX2N-10GM/FX2N-20GM] |
F2-RS-5CAB | 5 m | [Resolver extension cable for FX2N-1RM] |
Connection cable for peripheral devices
Model | Length | Description | |
| (1) E-20TP-CAB0 | 3 m | [E-20TP connection cable] |
(2) FX-20P-CAB0 | 1.5 m |
Spare parts
Model | Length | Description |
FX2N-GM-5EC | 55 mm | [Connection cable between PLC and FX2N-10GM/20GM] |
Network/Communication

Expansion options for CC-Link and Ethernet networks as well as RS-232C and RS-485 serial communication protocols are available.
FX series supports networking according to control needs, including high speed network with CC-Link and CC-Link/LT for reduced wiring.
Also, easily constructed simple data link between FX series and communication with RS-232C and RS-485 devices are supported
CC-Link
Model | Master station | Remote/slave | Distance | Applicable FX PLC | ||||||
FX | FX | FX | FX | FX | ||||||
1111111111 | FX3U-16CCL-M*1 | ○ | × | 1,200 m maximum | × | ○ | *4 | *2 | *2 | |
| FX2N-32CCL | × | ○ | 1,200 m maximum | × | ○ | ○ | *2 | *2 | |
| FX3U-64CCL | × | ○ | 1,200 m maximum | × | ○ | ○ | *2 | *2 |
*1: The FX3U-16CCL-M, FX2N-16CCL-M cannot be used at the same time with the FX2N-32ASI-M.
The FX3U-16CCL-M cannot be used at the same time with the FX2N-16CCL-M.
FX3U-16CCL-M and FX2N-16CCL-M cannot be used together.
[Remote I/O station]
Maximum 8 stations can be connected (1 station occupies 32 I/O points of the PLC)
[Total of remote device stations + intelligent device stations]
Maximum 8 stations can be connected (However, the total number of RX/RY points is 256 or less)
*2: When connecting to FX3GC,FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*3: FX3UC supported from version 2.20 or later.
*4: FX3U supported from version 2.20 or later.
CC-Link/LT
Model | Master station | Remote/slave | Applicable FX PLC | ||||||
FX | FX | FX | FX | FX | |||||
| FX2N-64CL-M | ○ | × | × | ○ | ○ | *1 | *1 | |
| FX3UC-32MT-LT | ○ | × | – | – | – | – | – | |
| FX3UC-32MT-LT-2 | ○ | × | – | – | – | – | – |
*1: When connecting to FX3GC,FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
CC-Link/LT: Power Adapter・Dedicated Power Supply
Model | Applicable FX PLC | ||||||||
FX | FX | FX | FX | FX | |||||
| CL1PAD1 | × | ○ | ○ | ○ | ○ | |||
CL1PSU-2A | × | ○ | ○ | ○ | ○ |
Ethernet
Model | Applicable FX PLC | |||||||
FX | FX | FX | FX | FX | ||||
| FX3U-ENET-L | × | × | *1 | × | *1 | ||
| FX3U-ENET-ADP | *7 | *3 | *4 | *3 | *4 |
*1: FX3U,FX3UC supported from version 2.21 or later.
*2: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*3: FX3G, FX3GC supported from version 2.20 or later.
*4: FX3U, FX3UC supported from version 3.10 or later.
*5: When connecting to FX3G, FX3G-CNV-ADP is required.
*6: When connecting to FX3U or FX3UC-32MT-LT(-2), a function expansion board is required.
*7: When connecting to FX3S, FX3S-CNV-ADP is required.
*8: When connecting to FX3S, supported by FX3U-ENET-ADP Ver.1.20 or later.
MODBUS
Model | Applicable FX PLC | |||||||
FX | FX | FX | FX | FX | ||||
| FX3U-232ADP-MB | *7 | *1 | *4 | *6 | *4 | ||
| FX3U-485ADP-MB | *7 | *1 | *4 | *6 | *4 |
*1: FX3G 14pt, 24pt models: 1 unit. 40pt, 60pt models: 2 units.
*2: When connecting to FX3G, FX3G-CNV-ADP is required.
*3: FX3G supported from version 1.30 or later.
*4: When connecting to FX3U,FX3UC-32MT-LT(-2), Function expansion board is required.
*5: FX3U, FX3UC supported from version 2.40 or later.
*6: FX3GC supported from version 1.40 or later.
*7: When connecting to FX3S, FX3S-CNV-ADP is required.
PROFIBUS
Model | Applicable FX PLC | |||||||
FX | FX | FX | FX | FX | ||||
1111111111111
| FX3U-64DP-M | × | × | *1 | × | *1 | ||
| FX3U-32DP | × | *4 | *1 | *5 | *1 |
*1: FX3U, FX3UC supported from version 2.21 or later.
*2: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*3: FX3UC-32MT-LT(-2) is not supported.
*4: FX3G supported from version 1.00 or later.
*5: When connecting to FX3GC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*6: FX3GC supported from version 1.40 or later.
Sensor Solution
Model | Applicable FX PLC | |||||||
FX | FX | FX | FX | FX | ||||
| FX3U-128ASL-M | × | *1 | *3 | *2 | *3 |
*1: FX3G supported from version 1.00 or later.
*2: FX3GC supported from version 1.40 or later.
*3: FX3U, FX3UC supported from version 2.20 or later.
*4: When connecting to FX3GC, FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
RS-232C communication
Model | Communication Function | Applicable FX PLC | ||||||||||
N:N network | Parallel Link | Computer Link | Non-Protocol Communication | Peripheral device communication | FX | FX | FX | FX | FX | |||
111111 | FX3G-232-BD | × | × | ○ | ○ | ○ | *10 | *1 | × | × | × | |
| FX3U-232-BD | × | × | ○ | × | *2 | ||||||
| FX3U-232ADP-MB | × | × | ○ | ○ | ○ | *11 | *1 | *4 | *9 | *4 | |
| FX2N-232IF | × | × | × | ○ | × | × | × | ○ | × | *5 |
*1: FX3G 14pt, 24pt models: 1 unit. 40pt, 60pt models: 2 units.
*2: Can only be connected to FX3UC-32MT-LT(-2).
*3: When connecting to FX3G, FX3G-CNV-ADP is required.
*4: When connecting to FX3U,FX3UC-32MT-LT(-2), Function expansion board is required.
*5: When connecting to FX3UC, FX2NC-CNV-IF or FX3UC-1PS-5V is required.
*6: For FX3UC-32MT-LT(-2), 7 units. For FX3UC-**MT/D, FX3UC-**MT/DSS, and FX3UC-16MR/D(S)-T, 8 units.
*7: FX3GC supported from version 1.30 or later.
*8: FX3U, FX3UC supported from version 2.40 or later.
*9: FX3GC supported from version 1.40 or later.
*10: Function expansion board and FX3S-CNV-ADP cannot be used together.
*11: When connecting to FX3S, FX3S-CNV-ADP is required.
RS-485 communication
Model | Communication Function | Applicable FX PLC | ||||||||||
N:N network | Parallel Link | Computer Link | Non-Protocol Communication | Peripheral device communication | FX | FX | FX | FX | FX | |||
111111 | FX3G-485-BD | ○ | ○ | ○ | ○ | × | *8 | *1 | × | × | × | |
| FX3G-485-BD-RJ | *8 | *1 | × | × | × | ||||||
| FX3U-485-BD | × | × | ○ | × | *2 | ||||||
| FX3U-485ADP-MB | ○ | ○ | ○ | ○ | × | *9 | *1 | *4 | *7 | *4 | |
FX-485PC-IF-SET RS-232C/RS-485 | × | × | ○ | × | × | ○ | ○ | ○ | ○ | ○ |
*1: FX3G 14pt, 24pt models: 1 unit. 40pt, 60pt models: 2 units.
*2: Can only be connected to FX3UC-32MT-LT(-2).
*3: When connecting to FX3G, FX3G-CNV-ADP is required.
*4: When connecting to FX3U,FX3UC-32MT-LT(-2), Function expansion board is required.
*5: FX3G supported from version 1.30 or later.
*6: FX3U, FX3UC supported from version 2.40 or later.
*7: FX3GC supported from version 1.40 or later.
*8: Function expansion board and FX3S-CNV-ADP cannot be used together.
*9: When connecting to FX3S, FX3S-CNV-ADP is required.
RS-422 communication
Model | Communication Function | Applicable FX PLC | ||||||||||
N:N network | Parallel Link | Computer Link | Non-Protocol Communication | Peripheral device communication | FX | FX | FX | FX | FX | |||
11111 | FX3G-422-BD | × | × | × | × | ○ | *3 | *1 | × | × | × | |
| FX3U-422-BD | × | × | ○ | × | *2 |
*1: FX3G 14pt, 24pt models: 1 unit. 40pt, 60pt models: 2 units.
*2: Can only be connected to FX3UC-32MT-LT(-2).
*3: Function expansion board and FX3S-CNV-ADP cannot be used together.
USB communication
Model | Communication Function | Applicable FX PLC | ||||||||||
N:N network | Parallel Link | Computer Link | Non-Protocol Communication | Peripheral device communication | FX | FX | FX | FX | FX | |||
111111
| FX3U-USB-BD | × | × | × | × | ○ | × | × | ○ | × | * |
*: Can only be connected to FX3UC-32MT-LT(-2).