CS1

Omron

The CS1 medium-sided building-block PLCs can be configured from a wide array of CPU Units, Special I/O Units, and CPU Bus Units. It handles everything from machine control to process control.

list of contents

CS1G, CS1H

From Machine Control to Information Management Multiple-application Controllers with a Wide Range of Functions

 

Product Format

Product Description

CS1G-CPU42H

CPU Unit , I/O 960 bits , 10K Steps

CS1G-CPU43H

CPU Unit , I/O 960 bits , 20K Steps

CS1G-CPU44H

CPU Unit , I/O 1280 bits , 30K Steps

CS1G-CPU45H

CPU Unit , I/O 5120 bits , 60K Steps

CS1H-CPU63H

CPU Unit , I/O 5120 bits , 20K Steps

CS1H-CPU64H

CPU Unit , I/O 5120 bits , 30K Steps

CS1H-CPU65H

CPU Unit , I/O 5120 bits , 60K Steps

CS1H-CPU66H

CPU Unit , I/O 5120 bits , 120K Steps

CS1H-CPU67H

CPU Unit , I/O 5120 bits , 250K Steps

CS1D

Redundant CPU Units, Power Supply Units, Communications Units, and Expansion I/O Cables

Product Format

Product Description

CS1D-CPU42S

CPU Unit, Single-CPU, I/O 960 Points, Program Capacity 10Ksteps, Programming Ladder

CS1D-CPU44S

CPU Unit, Single-CPU, I/O 1280 Points, Program Capacity 30Ksteps, Programming Ladder

CS1D-CPU44SA

CPU Unit, Single-CPU, I/O 1280 Points, Program Capacity 30Ksteps, Programming Ladder,FB,ST,SFC

CS1D-CPU65H

CPU Unit, Duplex-CPU, I/O 5120 Points, Program Capacity 60Ksteps, Programming Ladder

CS1D-CPU65P

Process-Control CPU Unit, CPU section:Equivalent to the CS1D-CPU65H

CS1D-CPU65S

CPU Unit, Single-CPU, I/O 5120 Points, Program Capacity 60Ksteps, Programming Ladder

CS1D-CPU67H

CPU Unit, Duplex-CPU, I/O 5120 Points, Program Capacity 250Ksteps, Programming Ladder

CS1D-CPU67HA

CPU Unit, Duplex-CPU, I/O 5120 Points, Program Capacity 250Ksteps, Programming Ladder,FB,ST,SFC

CS1D-CPU67P

Process-Control CPU Unit, CPU section:Equivalent to the CS1D-CPU67H

CS1D-CPU67S

CPU Unit, Single-CPU, I/O 5120 Points, Program Capacity 250Ksteps, Programming Ladder

CS1D-CPU67SA

CPU Unit, Single-CPU, I/O 5120 Points, Program Capacity 250Ksteps, Programming Ladder,FB,ST,SFC

CS1D-CPU68HA

CPU Unit, Duplex-CPU, I/O 5120 Points, Program Capacity 400Ksteps, Programming Ladder,FB,ST,SFC

CS1D-BC042D

CPU Backplane Unit, Especially for a Duplex CPU, Dual I/O Expansion System

CS1D-BC052

CPU Duplex Base Unit, 5 Slots

CS1D-BC082S

CPU Duplex Base Unit, Single-CPU

CS1D-BI082D

Expansion Backplane Unit, Especially for a Duplex CPU, Dual I/O Expansion System

CS1D-BI092

Expansion Back Unit For Online Unit Replacement

CS1D-ETN21D

Ethernet Unit, 100BASE-X, For Communication Duplex

CS1D-ATT01

Connection Cable Lock Parts

CS1D-DPL02D

Duplex Unit, Especially for a Duplex CPU, Dual I/O Expansion System

CS1D-IC102D

Control Unit, Especially for a Duplex CPU, Dual I/O Expansion System

CS1D-II102D

I/O Interface Unit, Especially for a Duplex CPU, Dual I/O Expansion System

CS1D-PA207R

Power Supply Unit, 100 to 240 VAC/200 to 240 VAC, Output 5 VDC 7A ,26 VDC 1.3A Total 35W

CS1D-PD025

Power Supply Unit, 24 VDC, Output 5 VDC 5.3A,26 VDC 1.3A Total 40W

 

Basic I/O Units

Basic I/O Units are available for essentially any application and wiring method.

CS1W-B7A

It transmits 16 points of I/O signals per word with a pair of cables. Easy and minimized wiring effort.

Unit
type

Name

Specifications

No. of
words
allocated

Current
consumption (A)

Model

Standards

I/O points

External
connection

5 V

26 V

CS
Series
Basic
I/O Units

B7A
Interface
Units

32 inputs

Removable
terminal block

2 words

0.09

CS1W-B7A12

UC1, CE

32 outputs

2 words

0.09

CS1W-B7A02

16 inputs/
outputs

2 words

0.09

CS1W-B7A21

32 inputs/
outputs

4 words

0.09

CS1W-B7A22

International Standards

  • The standards indicated in the “Standards” column are those current for UL, CSA, cULus, cUL, NK, and Lloyd standards and EC Directives as of the end of October 2008. (The standards are abbreviated as follows: U: UL, U1: UL Class I Division 2 Products for Hazardous Locations, C: CSA, US: cULus Class I Division 2 Products for Hazardous Locations, CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
  • Ask your OMRON representatives for the conditions under which the standards were met.

Special I/O Units

Special I/O Units can be used to handle advanced machine control needs, such as temperature control, position control, and communications.

CS1W-PTS

Provides the functionality of isolators, power supplies, signal converters, and other devices.

Isolated-type Thermocouple Input Units

Unit
type

Product
name

Input
points

Signal
range
selection

I/O type

Conver-
sion
speed

External
connec-
tion

No. of
unit
numbers
allocated

Current
consump-
tion (A)

Model

Stand-
ards

5V

24V

CS1
Special
I/O
Units

Isolated-
type
Thermo-
couple
Input
Units

4
inputs

Set
separately
for each
input

B, E, J, K, L,
N, R, S, T, U,
WRe5-26,
PLII,
± 100 mV

20 ms/
4 inputs,
10 ms/
2 inputs

Removable
terminal
block

1

0.12

0.08

CS1W-PTS11

UC1,
N, CE

4
inputs

R, S, K, J, T,
L, B

250 ms/
4 inputs

0.25

CS1W-PTS51

UC1,
CE

8
inputs

R, S, K, J, T,
L, B

250 ms/
8 inputs

0.18

0.06

CS1W-PTS55

4
inputs

B, E, J, K, N,
R, S, T,
± 80mV

150 ms/
4 inputs

0.15

0.15

CS1W-PTS01-V1

 

Isolated-type Resistance Thermometer Input Units

Unit
type

Product
name

Input
points

Signal
range
selection

I/O
type

Conver-
sion
speed
(resolu-
tion)

External
connec-
tion

No. of
unit
numbers
allocated

Current
consump-
tion (A)

Model

Stand-
ards

5V

24V

CS1
Special
I/O
Units

Isolated-
type
Resistance
Thermometer
Input Units

4
inputs

Set
separately
for each
input

Pt100,
JPt100,
Pt50,
Ni508.4

20 ms/
4 inputs,
10 ms/
2 inputs

Removable
terminal
block

1

0.12

0.07

CS1W-PTS12

UC1,
N, CE

4
inputs

Pt100,
JPt100

250 ms/
4 inputs

0.25

CS1W-PTS52

UC1,
CE

8
inputs

Pt100,
JPt100

250 ms/
8 inputs

0.18

0.06

CS1W-PTS56

4
inputs

Pt100,
JPt100

100 ms/
4 inputs

0.15

0.15

CS1W-PTS02

Isolated-
type
Resistance
Thermometer
Input Units
(Ni508.4 Ω )

4
inputs

Ni508.4

100 ms/
4 inputs

0.15

0.15

CS1W-PTS03

 

CS1W-CRM21

CS-series CompoNet Master Units Increase the Range of Applicability of Sensors and Actuators.

International Standards

  • The standards are abbreviated as follows: U: UL, U1: UL(Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
  • Contact your OMRON representative for further details and applicable conditions for these standards.

Name

Appear-
ance

Specifications

Number
of unit
numbers
allocated

Power
consumption (A)

Model

Stand-
ards

Type of com-
munications

Maximum number
of I/O points per
Master Unit

5-V
system

26-V
system

CS1
Special
I/O
Unit

Remote I/O
communications
Message
communications

Word Slave Units:
1,024 inputs and
1,024 outputs
(2,048 I/O points
total)
Bit Slave Units:
256 inputs and
256 outputs
(512 I/O points
total)

1, 2, 4,
or 8

0.4

CS1W-CRM21

CE, U,
U1, L,
N

Product
name

Specifications

Model

Stand-
ards

 

Number of
licenses

Media

CX-One FA
Integrated
Tool Package
Ver. 4.[]

The CX-One is a package that integrates the
Support Software for OMRON PLCs and
components. CX-One runs on the following OS.
Note: Windows XP (Service Pack 3 or higher,
32-bit version)/Windows Vista (32-bit/64-bit
version)/Windows 7 (32-bit/64-bit version)/
Windows 8 (32-bit/64-bit version)/
Windows 8.1(32-bit/64-bit version)/
Windows 10 (32-bit/64-bit version)

CX-One Ver. 4.[] includes CX-Integrator Ver. 2.[].
For details, refer to the CX-One catalog (Cat. No.
R134).

1 license
*

DVD

CXONE-AL01D-V4

* Multi licenses (3, 10, 30, or 50 licenses) and DVD media without licenses are also available for the CX-One.

CPU Units

I/O capacity / maximum number of configuration Units (Expansion Racks) : 2,560 points / 40 Units (3 Expansion Racks)

Product
name

Specifications

Model

Pro-
gram
ca-
pacity

Memory
capacity for
variables

Num-
ber
of
motion
axes

Data-
base
Conne-
ction
func-
tion

SECS/
GEM
Commu-
nication
function

Number
of
cont-
rolled
robots

Number
of
cont-
rolled
OMRON
robots

Numer-
ical
Control
Func-
tions

Database
Connection
CPU Units

20 MB

2 MB: Retained
during power
interruption
4 MB: Not
retained
during power
interruption

64

Yes

No

No

NJ501-1520

32

NJ501-1420

16

NJ501-1320

3 MB

0.5 MB:
Retained
during power
interruption
2 MB: Not
retained
during power
interruption

2

NJ101-1020

0

NJ101-9020

CS1W-PDC / PTW / PTR

Provides the functionality of isolators, power supplies, signal converters, and other devices.



Isolated-type DC Input Units

Unit
type

Product
name

Input
points

Signal range

Conver-
sion
speed
(resolu-
tion)

External
connec-
tion

No. of
unit
numbers
allocated

Current
consump-
tion (A)

Model

Stand-
ards

5V

24V

CS1
Special
I/O
Units

Isolated-
type DC
Input Unit

4
inputs

4 to 20 mA, 0 to 20 mA,
0 to 10 V, ± 10 V,
0 to 5 V, ± 5 V, 1 to 5 V,
0 to 1.25 V, ± 1.25 V

20 ms/
4 inputs,
10 ms/
2 inputs

Removable
terminal
block

1

0.12

0.12

CS1W-PDC11

UC1, N,
CE

8
inputs

4 to 20 mA, 0 to 10 V,
0 to 5 V, 1 to 5 V

250 ms/
8 inputs

0.18

0.06

CS1W-PDC55

UC1, CE

4
inputs

4 to 20 mA, 0 to 20 mA,
1 to 5 V, 0 to 5 V, ± 5 V,
0 to 10 V, ± 10 V

100 ms/
4 inputs

0.15

0.16

CS1W-PDC01

Isolated-
type
2-Wire
Transmitter
Input Unit

4
inputs

4 to 20 mA, 1 to 5 V

100 ms/
4 inputs

0.15

0.16

CS1W-PTW01

Power
Transducer
Input Unit

8
inputs

0 to 1 mA, ± 1 mA

200 ms/
8 inputs

0.15

0.08

CS1W-PTR01

Analog
Input Unit
(100 mV)

8
inputs

0 to 100 mV, ± 100 mV

200 ms/
8 inputs

0.15

0.08

CS1W-PTR02

 

CS1W-AD

For Various Analog I/Os

Analog Input Units

Unit type: CS-series Special I/O Units

Product
name

Specifications

Model

No. of
Unit
num-
bers
allo-
cated

Current
consump-
tion (A)

I/O
points

Signal
range
selection

Signal
range

Resolu-
tion

Conver-
sion
speed

External
connec-
tion

5V

26V

Analog Input
Units

4
inputs

Set
separately
for each
input

1 to 5 V,
0 to 5 V,
0 to 10 V,
– 10 V to
10 V,
4 to 20 mA

1/8,000
(Settable
to
1/4,000)

250 s/
point max.
(Settable
to 1 ms/
point)

Removable
terminal
block

CS1W-AD041-V1

1

0.12

0.09

8
inputs

1 to 5 V,
0 to 5 V,
0 to 10 V,
– 10 V to
10 V,
4 to 20 mA

1/8,000
(Settable
to
1/4,000)

250 s/
point max.
(Settable
to 1 ms/
point)

Removable
terminal
block

CS1W-AD081-V1

2

0.12

0.09

16
inputs

MIL
connector

CS1W-AD161

0.15

0.06

 

CS1W-
AD161
Connector-
Terminal
block
conversion
Units

Slim-type terminal block 34 terminal, dimensions: 128 × 40 × 39 mm

XW2D-34G6

Connecting cable
Length: 2 m

XW2Z-200C




CS1W-DA

For Various Analog I/Os

Analog Output Units

Unit
type

Prod-
uct
name

Specifications

Model

No. of
Unit
num-
bers
allo-
cated

Current
con-
sump-
tion (A)

I/O
points

Signal
range
selec-
tion

Signal
range

Reso-
lution

Con-
ver-
sion
speed

Ex-
ternal
con-
nec-
tion

5
V

26
V

CS1
Special
analog
I/O
Units

Analog
Output
Units

4
out-
puts

Set
sepa-
rately
for
each
input

1 to 5 V,
0 to 5 V,
0 to 10 V,
-10 V to
10 V, 4 to
20 mA

1/4,000

1 ms/
point

Re-
movable
terminal
block

CS1W-DA041

1

0.13

0.18

8
out-
puts

1 to 5 V,
0 to 5 V,
0 to 10 V,
-10 V to
10 V

1/4,000

1 ms/
point

CS1W-DA08V

0.13

0.18

8
out-
puts

4 to
20 mA

1/4,000

1 ms/
point

CS1W-DA08C

0.13

0.25

CS1W-PMV

Provides the functionality of isolators, power supplies, signal converters, and other devices.

International Standards

  • The standards indicated in the “Standards” column are those current for UL, CSA, cULus, cUL, NK, and Lloyd standards and EC Directives as of the end of September 2008. The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
  • Ask your OMRON representative for the conditions under which the standards were met.

Isolated-type Analog Output Unit

Unit
type

Product
name

Output
points

Signal
range
selection

Signal range

Conver-
sion
speed
(resolu-
tion)

External
connec-
tion

No. of
unit
numbers
allocated

Current
consump-
tion (A)

Model

Stand-
ards

5V

24V

CS1
Special
I/O
Units

Isolated-
type
Analog
Output
Unit

4
inputs

Set
separately
for each
input

4 to 20 mA,
1 to 5 V

100 ms/
4 inputs

Removable
terminal
block

1

0.15

0.16

CS1W-PMV01

UC1, CE

4
inputs

0 to 10 V, ± 10 V,
0 to 5 V, ± 5 V,
0 to 1 V, ± 1 V

40 ms/
4 inputs

0.12

0.12

CS1W-PMV02

 

CS1W-MAD44

For Various Analog I/Os

Analog I/O Units

Unit
type

Prod-
uct
name

Specifications

Model

No. of
Unit
num-
bers
allo-
cated

Current
con-
sump-
tion (A)

I/O
points

Signal
range
selec-
tion

Signal
range

Reso-
lution

Con-
ver-
sion
speed

Ex-
ternal
con-
nec-
tion

5
V

26
V

CS1
Special
analog
I/O
Units

Analog
I/O
Units

4
inputs

Set
sepa-
rately
for
each
input

1 to 5 V,
0 to 5 V,
0 to 10 V,
-10 V to
10 V, 4 to
20 mA

1/4,000

1 ms/
point

Re-
movable
terminal
block

CS1W-MAD44

1

0.20

0.20

4
out-
puts

1 to 5 V,
0 to 5 V,
0 to 10 V,
-10 V to
10 V

1/4,000

1 ms/
point



CS1W-PPS01

Provides the functionality of isolators, power supplies, signal converters, and other devices.

International Standards

  • The standards indicated in the “Standards” column are those current for UL, CSA, cULus, cUL, NK, and Lloyd standards and EC Directives as of the end of September 2008. The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
  • Ask your OMRON representative for the conditions under which the standards were met.



Isolated-type Pulse Input Unit

Unit type

Product name

Input points

External
connection

No. of unit
numbers
allocated

Current
consumption (A)

Model

Standards

5V

26V

CS1
Special
I/O Units

Isolated-type
Pulse Input Unit

4 pulse inputs

Removable
terminal block

1

0.2

0.16

CS1W-PPS01

UC1, CE

CS1W-NC[][]3

High-speed, High-precision positioning with 1, 2, or 4 axes

International Standards

  • The standards are abbreviated as follows: U: UL, U1: UL(Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
  • Contact your OMRON representative for further details and applicable conditions for these standards.

Position Control Unit

Unit
type

Name

Specifications

No. of
unit
numbers
allocated

Current
consumption (A)

Model

Standards

Control method/
Control output
interface

Number of
control
axes

5 V
system

26 V
system

CS1
Special
I/O
Units

Position
control
unit

 

Open-loop control
by pulse train
output/Open-
collector output

1 axis

1

0.25

CS1W-NC113

U, C, N,
L, CE

2 axes

0.25

CS1W-NC213

4 axes

2

0.36

CS1W-NC413

Open-loop control
by pulse train
output/Line-driver
output

1 axis

1

0.25

CS1W-NC133

2 axes

0.25

CS1W-NC233

4 axes

2

0.36

CS1W-NC433

 

Software

Name

Specifications

Number of
licenses

Model

Stand-
ards

CX-One FA
Integrated
Tool
Package
Ver. 4

The CX-One is a comprehensive software package that
integrates Support Software for OMRON PLCs and
components. CX-One runs on the following OS.
OS: Windows XP (Service Pack 3 or higher, 32-bit
version)/Windows Vista (32-bit/64-bit version)/Windows 7
(32-bit/64-bit version)/Windows 8 (32-bit/64-bit version)/
Windows 8.1 (32-bit/64-bit version)/Windows 10 (32-bit/
64-bit version)

CX-One Ver.4. [] includes CX-Position Ver.2. []. For
details, refer to the CXOne catalog (Cat. No.R134).

1 license *
DVD

CXONE-AL01C-V4

* Multi licenses (3, 10, 30, or 50 licenses) and DVD media without licenses are also available for the CX-One.

Servo Relay Units/Cables

Name

Applicable units

Applicable drives

Number
of
control
axes

Cable
length

Model

Standards

Servo
Relay
Unit

For CS1W-NC113/133
(No communication supported)

1 axis

XW2B-20J6-1B

For CS1W-NC213/233/413/433
(No communication supported)

2 axes

XW2B-40J6-2B

 

For CS1W-NC113/133/213/
233/413/433
(Communication supported)

2 axes

XW2B-40J6-4A

 

Position
Control
Unit
Cables
for
Servo
Relay
Unit

Open-
collector
output

For CS1W-NC113

OMNUC G/G5/W Series,
SMARTSTEP 2

1 axis

0.5m

XW2Z-050J-A6

1m

XW2Z-100J-A6

SMARTSTEP
Junior/A Series

0.5m

XW2Z-050J-A8

1m

XW2Z-100J-A8

For CS1W-NC213/413

OMNUC G/G5/W Series,
SMARTSTEP 2

2 axes

0.5m

XW2Z-050J-A7

1m

XW2Z-100J-A7

SMARTSTEP
Junior/A Series

0.5m

XW2Z-050J-A9

1m

XW2Z-100J-A9

Line-
driver
output

For CS1W-NC133

OMNUC G/G5/W Series,
SMARTSTEP 2

1 axis

0.5m

XW2Z-050J-A10

1m

XW2Z-100J-A10

SMARTSTEP
Junior/A Series

0.5m

XW2Z-050J-A12

1m

XW2Z-100J-A12

For CS1W-NC233/413

OMNUC G/G5/W Series,
SMARTSTEP 2

2 axes

0.5m

XW2Z-050J-A11

1m

XW2Z-100J-A11

SMARTSTEP
Junior/A Series

0.5m

XW2Z-050J-A13

1m

XW2Z-100J-A13

 

Communications Cables for Serial Communications Boards/Units

Name

Specifications

Applicable Serial
Communications
Units/Boards

Applicable
Servo Driver

Cable
Length

Model

Communications
Cables for Serial
Communications
Boards/Units

RS-422A Communications
cable (Servo Relay Unit
XW2B-40J6-4A required * )

CS1W-SCB41-V1
CS1W-SCU31-V1

OMNUC W Series,
SMARTSTEP A Series

1m

XW2Z-100J-C1

2m

XW2Z-200J-C1

* Communication Supported.

Accessories

The Position Control Unit includes the 48-pin solder-type connectors (socket: Fujitsu FCN-361J048-AU, cover: Fujitsu FCN-360C048-D/cover:OTAX N360C048D).

CS1W-CT021 / 041

High-Speed, Flexible Control With A Wide Array of Features

International Standards

  • The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
  • Contact your OMRON representative for further details and applicable conditions for these standards.

Unit
type

Product
name

Specifications

No. of
unit
numbers
allocated

Current
consumption
(A)

Model

Stand-
ards

Countable
channels

Encoder A and B inputs,
pulse input Z signals

Max.
counting
rate

5 V

26 V

CS1
Special
I/O
Unit

High-speed
Counter
Units

2

Open collector Input voltage:
5 V DC, 12 V DC, or 24 V DC
(only 1 axis for 5 V or 12 V
input)

50kHz

4

0.36

CS1W-CT021

UC, N,
L, CE

RS-422 line driver

500kHz

4

Open collector Input voltage:
5 V DC, 12 V DC, or 24 V DC
(up to 2 axes for 5 V or 12 V
input)

50kHz

0.45

CS1W-CT041

RS-422 line driver

500kHz

Accessories

The High-Speed Counter Unit includes the 40-pin solder-type connectors C500-CE404 (socket: Fujitsu FCN-361J040-AU, cover: Fujitsu FCN-360C040-J2/cover: OTAX N360C040J2).



Applicable Connectors

Name

Connection

Specifications

Model

40-pin
Connectors

Soldered

  

Connector:
Fujitsu FCN-361J040-AU
Connector Cover:
Fujitsu FCN-360C040-J2
OTAX N360C040J2
Right angle type, included with Unit

C500-CE404

Crimped

Housing:
Fujitsu FCN-363J040
OTAX N363J040
Contactor:
Fujitsu FCN-363J-AU
OTAX N363JAU
Connector Cover:
Fujitsu FCN-360C040-J2
OTAX N360C040J2
Right angle type

C500-CE405

Pressure welded

Fujitsu FCN-367J040-AU/F, w/o connector cover

C500-CE403

Soldered

40-pin, soldered, w/connector cover

C500-CE401

Crimped

40-pin, crimped w/connector cover

C500-CE402

Connector-Terminal Conversion Unit and Connection Cables

Product Name

Specifications

Model

For Connecting with
Terminal Block

Connecting Cables

Normal wiring

Cable length: 0.5m

XW2Z-050B

Cable length: 1.0m

XW2Z-100B

Cable length: 1.5m

XW2Z-150B

Cable length: 2.0m

XW2Z-200B

Cable length: 3.0m

XW2Z-300B

Cable length: 5.0m

XW2Z-500B

Connector-Terminal
Conversion Unit

Slim

40-pin M3 screw terminals

XW2D-40G6

CS1W-V680C11 / V680C12

Communication Unit Dedicated for RFID V680 Allowing Direct Connection to OMRON PLC CJ/CS/NJ-series

Type

Appearance

Connected ID
System

External
power
supply

No. of unit
numbers
used

Current consumption
(A)

Model

5 V

26 V

External

CS
Special
I/O Unit

V680
Series

1 Head

1 unit number

0.26

0.13 *

CS1W-V680C11

2 Heads

24 VDC

2 unit number

0.32

0.36

CS1W-V680C12

* When connected to the V680-H01-V2: 0.28 A

CPU Bus Units

CPU Bus Units handle special I/O and communications needs to achieve advanced position control, motion control, and network communications.

CS1W-EIP21

Introducing the New EtherNet/IP Unit. More Than 180,000 Words of Tag Data Link Capacity!

International Standards

  • The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA,
     UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC
     Directives.
    • Contact your OMRON representative for further details and applicable conditions for these standards.
    • Ask your OMRON representative for the most recent applicable standards for each model.

EtherNet/IP Unit

Unit
type

Product
name

Specifications

No. of
unit
numbers
allocated

Current
consump-
tion (A)

Model

Stand-
ards

Communi-
cations
cable

Communi-
cations
functions

Units
per
CPU
Unit

5 V
sys-
tem

24 V
sys-
tem

CS1
CPU
Bus
Unit

EtherNet/IP
Unit

Shielded twisted-
pair (STP) cable
Categories:
100 Ω at 5, 5e

Tag Data Link
Functions,
Message
Communications
Functions

8
max.

1

0.41

CS1W-EIP21

UC1,
N, L,
CE

Industrial Switching Hubs

Product
name

Appearance

Functions

No. of
ports

Accessories

Current
consumption (A)

Model

Industrial
Switching
Hubs

Quality of Service (QoS):
EtherNet/IP control data priority
10/100BASE-TX, Auto-Negotiation

5

Power supply
connector

0.07

W4S1-05D

Recommended Network Devices

The following table shows the devices recommended for use with the EtherNet/IP.

Part

Manufacturer

Model number

Inquires

Switching Hub

Phoenix Contact

FL SWITCH SFN 8TX (8 ports)

Phoenix Contact USA Customer Service

Contec USA, Inc.

SH8008(FIT)H (8 ports)

CONTEC USA Inc.

Cisco Systems, Inc.

WS-C2955T-12 (12 ports)

Cisco Systems, Inc. Main Corporate HQ

Twisted-pair
cable

100BASE-TX

EtherNet/IP compliant cable

Connectors
(Modular plug)

STP Plug

Panduit Corporation

MPS588

Panduit Corporation US Headquarters

Boots

Tsuko Company

MK boot (IV) LB

Tsuko Company Japan Headquarters

Note: 1. Always use a switching hub when using tag data links in the network.
          2. If a repeater hub is used for EtherNet/IP tag data links (cyclic communications), the network’s communications load
               will increase, data collisions will occur frequently, and stable communications will be impossible.

CS1W-SPU01-V2 / SPU02-V2

High-speed Collection of System Data

International Standards

  • The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
  • Contact your OMRON representative for further details and applicable conditions for these standards.
  • Refer to the OMRON website (www.ia.omron.com) or ask your OMRON representative for the most recent applicable standards for each model.

SPU Unit (High-speed Data Storage Unit)

Unit
type

Product
name

Specifications

No. of
unit
numbers
allocated

Current
consump-
tion (A)

Model

Stand-
ards

PC Card slot

Ethernet
(LAN) port

5 V

26 V

CS1
CPU
Bus
Unit

SPU Unit
(High-speed
Data Stor-
age Unit)

1 PC Card Type II slot
Insert an OMRON
HMC-EF[][][] to use
the Memory Card.

1 port
(10/100BASE-
TX)

1

0.56

CS1W-SPU01-V2

UC1, CE

2 ports
(10/100BASE-
TX)

0.7

CS1W-SPU02-V2

 

Support Software

Product name

Specifications

Model

Standards

SPU-Console
Support
Software

Functions:
Unit settings, sampling settings, etc., for High-speed Data Collection Units (required for making settings for this Unit)
OS:
Microsoft Windows 10 (32 bit/64 bit)
Microsoft Windows 8.1 (32 bit/64 bit)
Microsoft Windows 8 (32 bit/64 bit)
Microsoft Windows 7 (32 bit/64 bit)

WS02-SPTC1-V2

Option

Product
name

Specifications

Model

Standards

SPU Data
Management
Middleware

Function:
Data files collected by SPU Data Management
Middleware are automatically acquired at the
personal computer, and can be registered in a
database.
OS:
Microsoft Windows 10 (32 bit/64 bit)
Microsoft Windows 8.1 (32 bit/64 bit)
Microsoft Windows 8 (32 bit/64 bit)
Microsoft Windows 7 (32 bit/64 bit)
Microsoft Windows Server 2012
Microsoft Windows Server 2008

1 license

WS02-EDMC1-V2

5 licenses

WS02-EDMC1-V2L05

Memory
Cards

Flash memory, 128 MB

Note:
Memory Card
is required for
data collection.

HMC-EF183

N, L, CE

Flash memory, 256 MB

HMC-EF283

Flash memory, 512 MB

HMC-EF583

Memory Card Adapter (for a computer’s PCMCIA slot)

HMC-AP001

CE

Industrial Switching Hubs

Product
name

Appearance

Functions

No. of ports

Current
consumption (A)

Model

Industrial
Switching
Hubs

Quality of Service (QoS):
EtherNet/IP control data priority
10/100BASE-TX, Auto-Negotiation

5

0.07

W4S1-05D

Accessories

Model

Accessories

Specifications

CS1W-SPU01-V2
CS1W-SPU02-V2

PF-IN connector (premounted)

Connector for uninterruptible power supply PF-IN connection:
MC1.5/2-STF-3.81, manufactured by Phoenix Contact

CS1W-ETN21

Organically Connect the Production Site and Management

Applicable standards

Refer to the OMRON website or ask your OMRON representative for the most recent applicable standards for each model.

Ethernet Unit

Unit
type

Product
Name

Specifications

No.
of
unit
num-
bers
allo-
cated

Current
consump-
tion (A)

Model

Commu-
nications
cable

Communications
functions

Du-
plexing

Units
per
CPU
Unit

5 V
sys-
tem

26 V
sys-
tem

CS1
CPU
Bus
Unit

Ethernet
Units

100BASE-
TX Cable

FINS communications
service (TCP/IP and
UDP/IP), FTP server
function, socket
service, mail send
service, mail
reception (remote
command reception),
auto-adjustment of
PLC’s internal clock,
and server host name
specification

Not
sup-
ported

4
Units

1

0.38

CS1W-ETN21

Note: There is no accessory for the CS-series Ethernet Unit.

Recommended Network Devices

Product
name

Appearance

Functions

No. of
ports

Accessories

Current
consumption (A)

Model

Industrial
Switching
Hubs

Quality of Service (QoS):
EtherNet/IP control data priority
10/100BASE-TX, Auto-Negotiation

5

Power supply
connector

0.07

W4S1-05D

Industrial Switching Hubs

The following products are recommended for use with the Ethernet Unit.

Part

Maker

Model number

Specification

Hub

100BASE-TX

PHOENIX CONTACT

SWITCH 5TX

10/100 Mbit/s 5-port hub

Twisted-pair cable

EtherNet compliant cable

Connectors
(Modular plug)

STP Plug

Panduit Corp

MPS588

UTP Plug

Panduit Corp

MP588-C

CS1W-CLK

New Controller Link Units, Now with 4,000 Send Words



Controller Link Units

Unit
clas-
sifica-
tion

Product
name

Specifications

No. of
unit
numbers
allocated

Current
consump-
tion (A)

Model

Stand-
ards

Commu-
nications
cable

Commu-
nications
type

Duplex
support

Max. Units
mountable
per CPU
Unit

5 V
DC

26 V
DC

CS1
CPU
Bus
Unit

Controller
Link Unit

  

Wired
shielded
twisted-
pair cable
*1

Data links
and
message
service

No

8

1

0.33

CS1W-CLK23

UC1,
N, L,
CE

Controller
Link Unit

Optical
ring
H-PCF
cable *2

Yes. Unit
duplexing
and cable
loop back
are
supported.

Non-duplex:
8,
Duplex: 11
(6 Units
comprising
3 sets of
Duplex
Units + 5
Non-duplex
Units)

1

0.52

CS1W-CLK13

Controller
Link Unit

Optical
ring GI
cable *3

1

0.65

CS1W-CLK53

*1. Use the following special cable for shielded, twisted-pair cable.
       • ESVC0.5×2C-13262 (Bando Electric Wire: Japanese Company)
       • ESNC0.5×2C-99-087B (JMACS Japan Co., Ltd. : Japanese Company)
       • ESPC 1P×0.5mm2 (Nagaoka Electric Wire Co.,Ltd.: Japanese Company)
       • Li2Y-FCY2×0.56qmm (Kromberg & Schubert, Komtec Department: German Company)
       • 1×2×AWG-20PE+Tr.CUSN+PVC (Draka Cables Industrial: Spanish Company)
       • #9207 (Belden: US Company)
*2. When using a wire-to-optical (H-PCF) cable, use a H-PCF cable (for both Controller Link and SYSMAC LINK) or a
       H-PCF optical fiber cable with connector.
*3. When using a wire-to-optical (GI) cable, use a GI optical cable that matches the specifications.

Accessories

The Optical Fiber Cable Bracket is included in CS1W-CLK13 and CS1W-CLK53.

Controller Link Support Boards

Product name

Specifications

Accessories

Model

Stand-
ards

Communica-
tions cable

Communica-
tions type

Controller Link
Support Board
for PCI Bus

Wired shielded
twisted-pair
cable

Data links
and
message
service

• CD-ROM × 1 *
• INSTALLATION GUIDE (W467) × 1
• Communications connector × 1

3G8F7-CLK23-E

CE, KC

H-PCF optical
model

• CD-ROM × 1 *
• INSTALLATION GUIDE (W467) × 1
• Optical Fiber Cable Bracket × 1
• Power supply connector × 1

3G8F7-CLK13-E

CE

GI optical model

3G8F7-CLK53-E

* The CD-ROM contains the following software.
   • Controller Link (PCI) Driver
   • FinsGataway Version 2003 (PCI-CLK Edition)
   • FinsGataway Version 3 (PCI-CLK Edition)
   • Setup Diagnostic Utility
   • C Library

Repeater Units

Name

Specifications

Model

Standards

Controller Link
Repeater Unit

Wire-to-Wire Model

CS1W-RPT01

UC1, CE

Wire-to-Optical (H-PCF) Model *1

CS1W-RPT02

Wire-to-Optical (GI) Model *2

CS1W-RPT03

Using Repeater Units enables T-branches and long-distance wiring for Wired Controller Link networks, 62-node configurations, and converting part of the network to optical cable.
Note: 1. When using wire-to-optical (H-PCF) cable, use a H-PCF cable (for both Controller Link and SYSMAC LINK) or a
              H-PCF optical fiber cable with connector.
           2. When using wire-to-optical (GI) cable, use a GI optical cable (for Controller Link).

Relay Terminal Block

Name

Specifications

Model

Standards

Relay Terminal Blocks for
Wired Controller Link Units

Used for Wired Controller Link Units (set of 5)

CJ1W-TB101

Controller Link Units can be replaced without stopping the communications of the entire network if a Relay Terminal Block is installed in advance on the Unit in a Wired Controller Link network. Relay Terminal Blocks cannot be used on Controller Link Support Boards.

Duplex Optical Fiber Cable (H-PCF Cable)

Name

Application

Specifications

Model

Standards

Duplex Optical
Fiber Cable

CS1W-CLK13 or
CS1W-CLK12-V1 * in a CS1D system

H-PCF cable for connecting Duplex
Controller Link Units Cable length: 50 cm

CS1D-CN051

This cable is used to connect Units in active mode (ACT) and standby mode (STB) in a CS1D Duplex System.
* Discontinuation models in July 2012.

H-PCF Cables and Optical Connectors

Name

Application/construction

Specifications

Model

Standards

Optical Fiber Cables

Controller
Link,
SYSMAC
LINK,
SYSBUS

 

  1. Optical fiber
single-core cord
2. Tension member
(plastic-sheathed wire)
3. Filler (plastic)
4. Filler surrounding
signal wires (plastic,
yarn, or fiber)
5. Holding tape (plastic)
6. Heat-resistant
PV sheath

Two-
core
optical
cable
with
tension
member

Black 10 m

S3200-HCCB101

Black 50 m

S3200-HCCB501

Black 100 m

S3200-HCCB102

Black 500 m

S3200-HCCB502

Black 1000 m

S3200-HCCB103

Orange 10 m

S3200-HCCO101 *1

Orange 50 m

S3200-HCCO501 *1

Orange 100 m

S3200-HCCO102 *1

Orange 500 m

S3200-HCCO502 *1

Orange 1000 m

S3200-HCCO103 *1

Optical
Connectors
(Crimp-cut)

Controller Link:
CS1W-CLK13
CS1W-CLK12-V1 *1
3G8F7-CLK13-E
3G8F7-CLK12-EV1 *1
CS1W-RPT02
SYSMAC LINK:
CS1W-SLK11
3G8F7-SLK11-E *2
C200HW-SLK13/14 *1

Half lock

S3200-COCF2571

Controller Link:
CS1W-CLK13
CS1W-CLK12-V1 *1
3G8F7-CLK13-E
3G8F7-CLK12-EV1 *1
CS1W-RPT02
SYSMAC LINK:
3G8F7-SLK11-E *2

Full lock

S3200-COCF2071
*3

*1. Discontinuation models.
*2. Final order entry date:The end of March, 2020
*3. Full-lock Optical Connectors (Crimp-cut) (S3200-COCF2071) cannot be used with the CS1W-SLK11. Use a Half-lock
       Cable (S3200-COCF2571) or a H-PCF Optical Fiber Cable with Connector (S3200-CN[][][]-[][]-[][]).

H-PCF Optical Fiber Cables with Connectors (Black Composite Cables with Two-Optical Lines and Two Power Supply Lines)

Application

Appearance

Model

Standards

Controller Link,
SYSMAC LINK

 

S3200-CN[][][]-20-20

S3200-CN[][][]-20-25

S3200-CN[][][]-25-25

Optical connectors for H-PCF Optical Cables with Connectors are adhesive polished.

Cable Length

The following cable lengths are available: 2 m, 5 m, 15 m, and 20 m. For lengths of 21 m or more, contact your OMRON sales representative.

Model Numbers

Optical Connector Assembly Tool

Name

Applicable Unit

Model

Manufacturer

Standards

Optical Fiber
Assembly Tool *

This tool is used on site for mounting crimp-cut connectors
and hard plastic-clad silica optical fiber for optical transmission
systems of SYSMAC C-series SYSBUS, SYSMAC LINK, and
Controller Link.

CAK-0057

Sumitomo Electric
Industries, Ltd.

* There is a risk of quality problems when using cables assembled by typical users, so we recommend purchasing
  cables with preattached connectors or having a qualified technician assemble the cables.

CS1W-FLN22

Connect to Multivendor Controller Networks

International Standards

  • The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
  • Contact your OMRON representative for further details and applicable conditions for these standards.

FL-net Unit

 

Unit
type

Product
name

Specifications

No. of
unit
numbers
allocated

Current
consumption
(A)

Model

Standards

Communications
interface

Communications
functions

Max. Units
mountable
per CPU
Units

5V

26V

CS1
CPU
Bus
Unit

FL-net
Unit

100BASE-TX

With FL-net Ver. 2.0
specifications
(OPCN-2)
Data links and message
service

4

1

0.38

CS1W-FLN22

UC1, CE

Note: There is no accessory for the CS-series Ethernet Unit.

Recommended Network Devices

The following products are recommended for use with the FL-net Unit.

Part

Maker

Model number

Specification

Twisted-pair cable

EtherNet/IP compliant cable

Connector
(Modular plug)

STP Plug

Panduit Corp

MPS588

UTP Plug

Panduit Corp

MP588-C

CS1W-NC[]71

Decrease TCO with Simple Operation, Reduced Wiring, Batch Settings, and Batch Management



International Standards

  • The standards are abbreviated as follows: U: UL, U1: UL(Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
  • Contact your OMRON representative for further details and applicable conditions for these standards.

CS-series Units

 

Unit
type

Product
name

Specifications

No. of
unit
numbers
allocated

Current
con-
sumption
(A)

Model

Stand-
ards

Control output interface

No. of
axes

5 V

26 V

CS1
CPU
Bus
Units

MECHA-
TROLINK-II-
compatible
Position
Control
Units

Control commands executed by
MECHATROLINK-II synchronous
communications.
Direct operation by ladder
programming.
Control mode: Position control,
speed control, or torque control

2

1

0.36

CS1W-NC271

UC1,
CE

4

CS1W-NC471

16

CS1W-NCF71

 

Support Software

Product
name

Specifications

Number of
licenses

Media

Model

Stand-
ards

FA
Integrated
Tool
Package
CX-One
Ver. 4.[]

The CX-One is a comprehensive software package
that integrates Support Software for OMRON PLCs
and components. CX-One runs on the following OS.
OS: Windows XP (Service Pack 3 or higher, 32-bit
version)/Windows Vista (32-bit/64-bit version)/
Windows 7 (32-bit/64-bit version)/
Windows 8 (32-bit/64-bit version)/
Windows 8.1 (32-bit/64-bit version)/
Windows 10 (32-bit/64-bit version)

CX-One Ver. 4.[] includes CX-Motion-NCF Ver. 1.[].
For details, refer to the CX-One catalog (Cat. No.
R134).

1 license
*

DVD

CXONE-AL01D-V4

* Multi licenses (3, 10, 30, or 50 licenses) and DVD media without licenses are also available for the CX-One.

MECHATROLINK-related Devices and Cables (Manufactured by Yaskawa Corporation)

Name

OMRON
model number

Yaskawa
model number

MECHATROLINK-II Cables
(with ring core and USB connector on
both ends)

0.5 m

FNY-W6003-A5

JEPMC-W6003-A5

1.0 m

FNY-W6003-01

JEPMC-W6003-01

3.0 m

FNY-W6003-03

JEPMC-W6003-03

5.0 m

FNY-W6003-05

JEPMC-W6003-05

10.0 m

FNY-W6003-10

JEPMC-W6003-10

20.0 m

FNY-W6003-20

JEPMC-W6003-20

30.0 m

FNY-W6003-30

JEPMC-W6003-30

MECHATROLINK-II Terminating Resistor

Terminating resistance

FNY-W6022

JEPMC-W6022

MECHATROLINK-II Repeater

Communications
Repeater

JEPMC-REP2000-E

Note: MECHATROLINK-related Devices and Cables are manufactured by Yaskawa Corporation, but they can be ordered
          directly from OMRON using the OMRON model numbers. (Yaskawa-brand products will be delivered even when
          they are ordered from OMRON.)

CS1W-DRM21-V1

A DeviceNet Unit for the CS Series That Boasts Industry-leading Performance and Functions

International Standards

  • The standards are abbreviated as follows: U: UL, U1: UL(Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
  • Contact your OMRON representative for further details and applicable conditions for these standards.

Product

Appearance

Specifications

Model

Stand-
ards

 

Number
of
licenses

Media

DeviceNet
Unit

For CS Series
Functions as either a master or a slave.
2,048 I/O points

CS1W-DRM21-V1

UC1,
N, L,
CE

 

CX-One FA
Integrated
Tool Package
Ver.4.[]

The CX-One is a package that
integrates the Support Software for
OMRON PLCs and components. CX-
One runs on the following OS.
OS: Windows XP (Service Pack 3 or
higher, 32-bit version)/
Windows Vista (32-bit/64-bit version)/
Windows 7 (32-bit/64-bit version)/
Windows 8 (32-bit/64-bit version)/
Windows 8.1 (32-bit/64-bit version)/
Windows 10 (32-bit/64-bit version)

CX-One Ver.4.[] includes CX-Integrator
Ver.2.[].
For details, refer to the CX-One catalog
(Cat. No. R134).

1 license
*

DVD

CXONE-AL01D-V4

* Multi licenses (3, 10, 30, or 50 licenses) and DVD media without licenses are also available for the CX-One.

Communications Coupler

Coupler Unit which enables EtherCAT or EtherNet/IP network communications.